Archived source flow
Technical notes
Potentiometer control
Every loop maps the expected 0–1023 analog input range to 0–127 and sends CC7. The source does not suppress unchanged potentiometer values.
Encoder and buttons
A change on encoder channel A selects CC44 value 1 or 127 according to channel B, then saves A. Changes on two button inputs set press/release flags that produce note-on/off events for notes 60 and 61.
Source limits
The source polls inputs without a debounce layer or analog filtering. Cached button states start low and may produce initial release messages. Nano is the target named in the portfolio index; the file does not provide a board build configuration. Compilation and MIDI hardware operation are unverified.