Firmware combining two current-monitored motor outputs, button handling and relay indication.

Firmware development
Current monitoringRelay controlMotor control

Firmware flow

Evaluate current flags and a motion timeout

Selected CLAMPING branch from current-monitored motor firmware.

Each current comparison can set its own remembered flag. Both motors are stopped after both flags are set, or after the configured timeout, before the code changes the outputs and returns to idle.

This source fragment does not establish current calibration, independent per-motor cutoff, fail-safe behavior or suitability for a vehicle.

Read the implementation

Selected firmware excerpts. The diagram explains the code; it is not a hardware test.

Two unchanged source segments are shown separately; they are not a complete function. Source line 316, containing the stop call and its diagnostic string, is omitted from display. The flow follows the reviewed full branch at lines 309–321.

Excerpt segment 1: current flags and completion condition

    case CLAMPING: {
      float i1 = readCurrentA(PIN_CS_M1);
      float i2 = readCurrentA(PIN_CS_M2);
      if (i1 >= CURRENT_THRESHOLD_A) m1Reached = true;
      if (i2 >= CURRENT_THRESHOLD_A) m2Reached = true;

      if ((m1Reached && m2Reached) || (now - motionStart >= motionTimeout)) {

Excerpt segment 2: indicator outputs and return to idle

        setLedSolid(true);                          // LED ON solid
        relayValue = RELAY_ON_LEVEL(); setOutputs();// D2 HIGH (or active level)
        state = IDLE;
      }
    } break;
ActionRead both current inputs
ActionLatch each threshold crossing
CheckBoth flags set or timeout reached?
ResultKeep this movement active
ActionSet the LED and relay output states
ResultReturn to the idle state

Technical notes

Current checks

The CLAMPING branch reads both current inputs and remembers when each crosses its configured threshold. Both motors stop after both flags are set, or when the movement timeout expires.

Outputs and state

After stopping, the branch sets the indicator and relay outputs and returns to idle. Button handling timestamps raw input transitions; it does not implement the debounce constant declared elsewhere in the sketch.

Implementation limits

The current conversion uses configured scale values. The source does not establish calibration, independent per-motor cutoff or suitability for a vehicle; this is firmware inspection, not a hardware validation result.